Technova: Renewal Energy
Showing posts with label Renewal Energy. Show all posts
Showing posts with label Renewal Energy. Show all posts

Wind Power Direct Drive Control System Scheme


Grid-side Inverter Control Scheme


1. Electric Circuit Model
2. Mathematical Model


3. Controlled Object
4. Control System Scheme



Motor-side Inverter Control Scheme

1. DQ Mathematical Model



2. Electric Circuit Model


3. Control System Scheme Model


4. Speed Sensorless Observer




The DCDC Converter Circuit Design in Electrical Vehicle

The DCDC Converter Circuit Design in Electrical Vehicle


1.  DCDC  Converter Design- spec

Input voltage:                                210Vdc~410Vdc
Output voltage:                             14V1500W
Output voltage adjustable range:   12~16Vdc,  PWM signal control
Regulation:                                      ±1%
Start up overshoot:                        ± 5%
Transient response:                      1ms, 0%~50%~0%  1000A/s
                                                         0%~100%~0%  1000A/S
Ripple:                                          200mV
Efficiency:                                     92%
Protection function:                     Input under voltage: Automatic recover
                                                         Input over voltage: Automatic recover
                                                         Output under voltage: Automatic recover
                                                         Output over voltage: Latch
                                                         Over load/short circuit: Automatic recover
                                                         Over temperature: Automatic recover
Remote control:                              TTL level voltage

Fault alarm:                                     OC alarm

Mechanical outline:                      280mm×200mm×70mm
Weight:                                          3.6kg
Operation temperature:              -40~85 ℃
Cooling:                                         Water cooling ( water temperature: 75℃)
                                                          ( water press is from 0.02Mpa)
EMC:                                              CISPR 25, Level 4

Vibration:                                       QC/T 413-2002 3.12,   Not on the Engine in engine  
                                                       cabinet 
Protection:                                    IP66








2. DCDC  Converter Design- Circuit 


(1).             EMI stage:
                   Four common mode inductor: 2.1mH, R7K, T25X15X10, 1.2mm, 23T





(2). Buck+ open loop interleaved LLC
   Buck: Mosfet: 20N60,  Diode:R1560
  Inductor: 2X56uH, CS234090, FeSiAl, 1.0mmX3, 20T
  UC2843  IRS21834
  Switching frequency:   100KHz






(3). Open loop Interleaved LLC
    Primary Mosfet: IRF38N20,  Synchronous Rectifier: IRF3805
    Lm: 18uH,  Lr: 2.6uH,  Cr:39nF
    Lr:  2.6uH, PQ26, PC95, 0.25X3.5X4, 3T
    Transformer: ER30, PC95, Primary 4OZ PCBX2, 5T
    Secondary 0.2X4.5mm copperX6, 1T
    Output Capacitor: 10uFx17
    Switch frequency: 300kHz  







(4). Auxiliary Power Supply
      Transformer: EFD20, PC40
      Mosfet:          9R1K20
     Control IC:    UC2844
     Switching frequency: 130KHz







Calculation of Inductance of chokes to be used for the paralleling of the Inverters

For the calculation of the Inductance of the chokes to be used to parallel the two inverters, we take into consideration the following two possibilities:

1. The corresponding parallel arms +ve & -ve are connected directly to one another (i.e. using busbars) as a result of which the inductance at the input is negligible.

2. The corresponding paralllel arms +ve & -ve are both connected to the output of the bridge rectifier as a result of which the inductance of these connections must be taken into consideration.

In the diagrams, for clarity, only one arm of each inverter has been shown and the possible connection of the DC busbars at the inut of each arm. It must be understood that for the entire system, there would be 3 such arms per inverter, giving therefore the 3-phase output.

Case 1

Direction connection of DC Inputs of paralleled Inverters



Here we have,

maximum value of Vdc = 850V

maximum delay between switching OFF of one TOP IGBT and switching ON of one BOT IGBT, Dt = 125 ns (i.e. the maximum possible time delay between the control pulse being received at the IGBTs and the IGBTs switching as a result)

say, maximum allowed DiSC = 10 A

Therefore,

Lac = 850 /(2 x 10)x 0.125 µH
       = 42.5 * 0.125 µH
       = 5.3125 µH
Lac = approx 5 µH

Case 2
Connection of Inputs of paralleled Inverters to Input bridge rectifier.


In this case, the additional inductance at the outputs of the bridge recifier will serve another purpose i.e. to smoothen the ripples in the output of the bridge circuit.


The Analysis and Design of Photovoltaic Inverter



















Leon Song
Xia(Lily) Yu
+1 916-793-0676
(Texting Only)
Wechat 微信 ID
Leon_Song_PhD

SEND ME A MESSAGE